Fan Convectors

What size Kickspace is suitable to heat a room?

Kickspace should be sized based on the heat loss of the room, Myson have an easy to use heat loss manager please click here...

What is the minimum pipe size required for Kickspace (excludes electric models)?

The pipes should be sized based on the flow rate requirement of the product and should be no less than 15mm, all Kickspace products require a flow rate of 340 l/hr. Note: If pipes are under sized then a potential issue will be lack of heating performance and possible the fan switching on/off intermittently.

Is it possible to use an external thermostat to control Kickspace?

Yes, it is possible to use the range of accessories sold separately by Myson. Note: Only one Kickspace can be controlled via a single external control also the controls are only compatible with Kickspace 500, 600, 600-12V and 800 models therefore are not compatible with the Kickspace electric or Duo models.

Can a single remote thermostat / remote switch to control multiple Kickspace products?

No, when using the Myson Kickspace accessories only one Kickspace can be controlled via a single external thermostat. If this application is required then a traditional thermostat (not the Kickspace thermostat accessory) must be used to control the live supply to the Kickspace only.

Kickspace is blowing out cold air?

Please ensure the Kickspace is in heating mode (Sun icon) If the Kickspace is in fan-only mode (snowflake) then the fan will run continuously until manually switched off.

Why does the fan on a Kickspace not switch off?

Please ensure the Kickspace is in heating mode (Sun icon) If the Kickspace is in fan-only mode (snowflake) then the fan will run continuously until manually switched off.

Why is the fan on Kickspace switching on/off intermittently?

This would indicate a lack of flow rate from the heating system, some possible ways to check this would be to test them temperatures of the flow and return pipes they should both be piping hot therefore if one is hot and the other is noticeably cooler then this would suggest a lack of flow rate in the system. Another way to test this would be to turn all the radiators on the heating system off thus directing all available flow rate to the Kickspace and allowing it to work correctly. Some reasons for this could be incorrect pipe sizes or undersized pump/faulty pump. On this occasion please contact your installer.

What Kickspace products are the remote thermostat and switches compatible with?

The Kickspace remote switch and thermostats are compatible with the Kickspace 500, 600, 600-12V and 800 models and therefore are not compatible with the Kickspace electric and Duo models.

How does Kickspace work with a central heating system?

Every hydronic Kickspace is fitted with a low limit thermostat, meaning when the central heating switches on and the pipes warm up the sensor will activate the fans. Then when the central heating systems is off and the pipes cool down the sensor will switch the fans off.

What size Hi-Line, Lo-Line or Slim-Line is suitable to heat a room?

Hi-Line, Lo-Line and Slim-Line should be sized based on the heat loss of the room, Myson have an easy to use heat loss manager please click here...

What is the minimum pipe size required for Hi-Line, Lo-Line and Slim-Line?

The pipes should be sized based on the flow rate requirement of the product and should be no less than 15mm on Hi-Line RC/Hi-Line LV/Lo-Line RC/Slim-Line RC and no less than 22mm on Hi-Line Super RC.  All Hi-Line, Lo-Line or Slim-Line products require a flow rate of 340 l/hr. Note: If pipes are under sized then a potential issue will be lack of heating performance and possible the fan switching on/off intermittently. 

How does Hi-Line, Lo-Line and Slim-Line work with a central heating system?

Every Hi-Line, Lo-Line and Slim-Line is fitted with a low limit sensor, meaning when the central heating switches on and the pipes warm up the sensor will activate the fans. Then when the central heating systems is off and the pipes cool down the sensor will switch the fans off.

What size iVector is suitable to heat a room?

iVector should be sized based on the heat loss of the room, Myson have an easy to use heat loss manager please click here...

What is the minimum pipe size required for iVector?

The pipes should be sized based on the flow rate requirement of the product and should be no less than 15mm. The minimum flow rate will vary depending on the size of iVector being installed and can range between 340 – 800 l/hr Please refer to the installation manual for more information. Note: If pipes are under sized then a potential issue will be lack of heating performance and possible the fan switching on/off intermittently.

How does iVector work with a central heating system?

Every iVector is fitted with a low limit sensor, meaning when the central heating switches on and the pipes warm up the sensor will activate the fans. Then when the central heating systems is off and the pipes cool down the sensor will switch the fans off.